Delivering Excellence For Your Lab Needs

UPDATE:Discover Canadian Lab's Cannabis Solutions

Brand: Thermo Scientific UV-Vis

GENESYS 30 VIS Spectrophotometer

Description

The Thermo Scientific™ GENESYS™ 30 is the most thoughtfully designed spectrophotometer available today. Its high resolution color display, large sample compartment, and data export options meet modern expectations for students, educators and lab technicians. The GENESYS 30 blends the simplicity to satisfy novice students with the capabilities that labs need for accurate quantitative analysis. The GENESYS 30 is the Visible Solution for your laboratory.

Designed for usability

  • Large removable and washable sample compartment
  • Big, high resolution color screen that’s easy to read
  • Familiar keypad controls for easy routine use

6-point quant offers high data confidence

Scanning available with on board software

Save and retrieve methods using the onboard library

Backed by a two-year warranty and skilled technical support

  • Quality and Dependability from a global leader

Data any way you want it

  • USB data export
  • Snap-on thermal printer

Design Features

  • Removable, washable sample compartment
  • Easy-access top-and-front sample comp't lid
  • 5 inch/12.7cm color graphical display; 800 x 480 pixels
  • Tactile rubber keypad with number pad
  • Sloping surfaces to shed spills

Includes: Dust cover and 5 disposable plastic cuvettes

Optional: Direct connect thermal printer, Sample compartment holders for test tubes and long path cuvettes

Accessories for GENESYS 30

CL7500 Test-Tube Holder

  • Accomodates one test-tube from 12mm OD to 25mm OD
  • Comes assembled in a removable sample compartment liner
  • Optional: Add tall test-tube cap, 1182H20 to use with test-tubes taller than 104mm

CL7600 Tall Test-Tube Cap 

  • Covers test-tubes up to 15cm/6 inches tall to allow measurements while the sample compartment lid is open
  • Requires 1182H19 Test-Tube Holder for GENESYS 30

CL7700 Long Path Rectangular Cell Holder

  • Holds one rectangular longpath cell 20 - 100mm pathlength
  • Comes assembled in a removable sample compartment liner

CL7800 5-100mm Path Cylindrical Cell Holder

  • Holds one cylindrical longpath cell 5 - 100mm pathlength
  • Comes assembled in a removable sample compartment liner

CL8100 Film/Filter Holder

  • Accommodates filters/lenses up to 50 mm long x 80 mm tall x 1-8 mm thick
  • Comes assembled in a removable sample compartment liner

CL8200 Accessory Kit for Hose Entry/Exit

  • Replacement sample compartment lid and liner with ports to allow hoses to enter and exit
  • Required to support to support thermostatted cell holder or flow cell
  • Requires suitable cell holder such as: Thermostatted Cell Holder 335079-000 or Standard 10mm Square Cell Holder (8421A70)

CL8000 Printer Accessory 

  • Printer attaches directly to instrument behind screen
  • Easy drop-in paper re-loading
  • Uses 80mm wide thermal paper rolls
  • Includes: 1 roll thermal paper
  • Optional: Self Stick Printer Paper (1189N87) or Ordinary Printer Paper (1182H26)

CL8300 Standard Printer Paper

  • Package of 10 rolls
  • 80mm width x 50mm roll diameter
  • Typical legibility = 5 years

CL8700 Tungsten-Halogen Lamp Assy

  • Pre-aligned, pre-assembled replacement lamp
  • Customer replaceable - slides into place
  • Mouse-hole replacement access. Cover removal not required.
  • For GENESYS 30 Vis only

CL8400 Replacement Sample Compartment Lid

  • Standard sample compartment lid
  • User installable with basic tools

CL8600 10mm Square Cell Holder for GENESYS 30

  • Replaces the standard cell holder shipped with the instrument
  • Cuvette holder can be removed and replaced with specialty cell holders used with earlier GENESYS instruments

Measurement Modes
Live Display in Abs, %T or Concentration
Scanning
Fixed wavelength at 1 or 2 wavelengths with calculations
Quantitative Analysis
OD600 analysis
Programmable method library
Smart Start direct boot-up
Technical Specifications
Single beam, Czerny-Turner optical system
Tungsten-Halogen lamp
Silicon photodiode detector
Wavelength Measurement Range: 325 - 1100nm
Wavelength Accuracy: ± 2nm
Wavelength Repeatability: < ±1mn
Photometric Display Range: -3A to +3A
Photometric accuracy ±0.002A from 0.0 to 0.3A. ±0.5% of ABS reading from 0.3A to 2.5A
Spectral bandwidth = 5nm
Noise: <=0.001A at 0A; <=0.001A at 1A; <=0.002A at 2A
Drift: <0.002A/hr
Canlab #MFR #DescriptionUnitPrice
CL7000840-277000GENESYS 30 VIS Spectrophotometer, 100-240V
1/EARequest For Price
CL7500840-277500Test-Tube Holder
1/EARequest For Price
CL7600840-277600Tall Test-Tube Cap
1/EARequest For Price
CL7700840-277700Long Path Rectangular Cell Holder
1/EARequest For Price
CL7800840-2778005-100mm Path Cylindrical Cell Holder
1/EARequest For Price
CL8100840-278100Film/Filter Holder
1/EARequest For Price
CL8200840-278200Accessory Kit for Hose Entry/Exit
1/EARequest For Price
CL8000840-278000Printer Accessory
1/EARequest For Price
CL8300840-278300Standard Printer Paper
1/EARequest For Price
CL8700840-278700Tungsten-Halogen Lamp Assy, Pre-aligned
1/EARequest For Price
CL8400840-278400Dust Cover
1/EARequest For Price
CL8600840-27860010mm Square Cell Holder
1/EARequest For Price