Delivering Excellence For Your Lab Needs

UPDATE:Discover Canadian Lab's Cannabis Solutions

Brand: Thomos

TS-M Series Analytical Balance

Description

The built-in security features on MS-TS analytical balances ensure results are always valid. Operators receive a warning if any problems are encountered or tolerances are not adhered to. Corrective actions can be taken immediately, avoiding costly reworking later.

LevelControl, MinWeigh and automatic internal adjustment with proFACT support compliance with regulations. The ISOLog function maintains a record of all weighing relevant changes to the balance’s settings. For additional security, settings can be passcode protected.

The 7” extra-large color TFT touchscreen display is operable through cotton, silicon and rubber gloves. An intuitive user interface and 18mm high digits bring comfort to your daily tasks.

Built-in function simplifies balance leveling
The built-in LevelControl function issues a warning when the balance is not level and provides onscreen guidance to help you level the balance correctly within seconds.

MinWeigh function ensures process tolerances
The weight value remains red until the net sample is above the pre-programmed minimum value. A user-defined minimum weight can also be programmed into the balance to provide an additional safety factor.

Passcodes protect balance settings
Create a passcode to restrict modification of balance settings to authorized personnel only – functions that affect metrological performance are protected against accidental alteration.

Easy-cleaning features save time and effort
Remove, clean and replace all of the QuickLock draft shield glass panels in just a few simple steps, without tools and without moving the balance. The housing has smooth surfaces and rounded edges for easy cleaning.

 

Limit values
Maximum capacity120 g220 g220 g
Readability0.1 mg0.1 mg0.1 mg
Tare range (from … to)0 … 120 g0 … 220 g0 … 320 g
Repeatability (nominal) (sd)0.1 mg (100 g)0.1 mg (100 g)0.1 mg (100 g)
Linearity deviation (test load)0.2 mg (20 g)0.2 mg (50 g)0.2 mg (50 g)
Eccentricity deviation (test load)10.4 mg (50 g)0.4 mg (100 g)0.4 mg (100 g)
Sensitivity offset (test weight)0.8 mg (100 g)1 mg (200 g)1.5 mg (300 g)
Sensitivity temperature drift 21.5 ppm/°C1.5 ppm/°C1.5 ppm/°C
Sensitivity stability 32.5 ppm/a2.5 ppm/a2.5 ppm/a
Typical values
Repeatability (at low load)0.08 mg0.08 mg0.08 mg
Linearity deviation0.06 mg0.06 mg0.06 mg
Eccentric deviation (test load) 10.1 mg (50 g)0.12 mg (100 g)0.12 mg (100 g)
Sensitivity offset (test weight)0.2 mg (100 g)0.24 mg (200 g)0.6 mg (300 g)
USP minimum sample weight
(5% load, k=2, U=0.10%)
160 mg160 mg160 mg
Minimum sample weight
(5% load, k=2, U=1%)
16 mg16 mg16 mg
Settling time2 s2 s3 s
Weighing pan dimensions (mm)ø 90ø 90ø 90
  1. according to OIML R76
  2. in the temperature range 10 to 30°C
  3. Stability of sensitivity with proFACT self-adjustment switched on; s: seconds; a: year (annum); sd: standard deviation

CanLab No.DescriptionQty/Uom
####38D8811***MS104TS Analytical Balance, 120g x 0.1mg1/EA
####48D8811***MS204TS Analytical Balance, 220g x 0.1mg1/EA
####58D8811***MS304TS Analytical Balance, 320g x 0.1mg1/EA
####15J0021***Analytical Balance 120 x 0.0001 g, Internal Cal1/EA
####55J0021***Analytical Balance 120 x 0.0001 g1/EA
####1200J56****Analytical Balance 220 x 0.0001 g1/EA

We use cookie to improve your experience on our site. By using our site you consent cookies.